Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage

GeneralRMR-36/40.5kV is completely insulated SF6 Gas insulated Switchgear.This product is in conformity with the standards the GB/IEC standard and the design of a high safety combined switch cabinets.The system of RMR-36/40.5kV of combined switch cabinets can be divided into three kinds of unit cabinet:++++ 3 position cable conn

Featured Products

General

RMR-36/40.5kV is completely insulated SF6 Gas insulated Switchgear.
This product is in conformity with the standards the GB/IEC standard and the design of a high safety combined switch cabinets.

The system of RMR-36/40.5kV of combined switch cabinets can be divided into three kinds of unit cabinet:

++++ 3 position cable connection unit (Cable switch unit), additional live shows and configuration of surge arresters and grounding fault component. Code C

++++3 position switch and fuse tripping system and earthing switch interlock system fuse combined electrical unit (Fuse combination unit), additional live shows and configuration of surge arresters and grounding fault component. Code F

++++3 position switch and vacuum circuit breaker combined appliances unit (Vacuum circuit breaker unit), additional current transformer, live shows and configuration of surge arresters and grounding fault component. Code V

The combination of the current transformer and the microcomputer protection to constitute the basic circuit protection function.

Microcomputer protection using passive protection and CT electric no need of additional PT

Main technical specifications

 
NoItemUnitData
1Rated voltagekV24/36
2Power Frequency withstand voltageDry60/70/80/95
Wet
Lightning Impulse withstand Voltage
(peak value)
125/150/170/185/200
3Rated CurrentA630/1250/2500
4Rated short circuit breaking current (peak)kA20/25(V) 31.5(F)
5Rated closed-loop breaking currentA630/1250(C)
6Rated cable charging interrupting currentA50(C)
7Rated line cable charging interrupting currentA10(C)
 Rated off circuit transformer breaking currentA16
8Rated making current (peak)kA50(63/80)/2.5(main switch/grounding)
9Rated  withstand current (peak)
10Rated short time withstand current16/20/25/31.5
11Rated short time withstand timeS3/4
12Mechanical lifetimesC/F(2000)V(10,000)
13Main busbarA630/1250/2000/2500
More details pls consult with us!Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage
Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage
Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage
Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage
Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage
Gas Insulated Cubicle Switchgear 12kv 630A Gis C-Gis High Voltage

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours